Interlogix NS4702-24P-4S-4X Command Line Guide Uživatelský manuál Strana 241

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 434
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 240
-241-
Example:
To configure Static MAC Address Table as below table
Switch# configure terminal
Switch (config)# mac address-table static 00:11:22:33:44:55 vlan 1 interface
GigabitEthernet 1/1
4.2.123 mep <Instance> ais
Command:
mep <Instance> ais [ fr1m | fr1s ] [ protect ]
mep Maintenance Entity Point
<Instance> The MEP instance number.
ais Alarm Indication Signal
fr1m Frame rate is 1 f/min.
fr1s Frame rate is 1 f/s.
protect The AIS can be used for prote ction. At the p oint of st ate chan ge three AIS PDU is transmitted as fast as
possible.
Default:
None
Usage Guide:
To configure AIS of MEP
Example:
To configure AIS of MEP 1 as below table
Switch# configure terminal
Switch (config)# mep 1 ais fr1s
Zobrazit stránku 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 433 434

Komentáře k této Příručce