Simon XT Installation Manual 17
Installation
This section describes how to open the panel for mounting, mount the panel,
connect sirens, connect hardwired contacts, and connect the AC power
transformer.
UL listed installations
Some installations may require configurations dictated by city/state codes,
insurance, or Underwriters Laboratories (UL). This section describes the various
component and configuration listings.
Basic system:
Control panel: backup battery 6 V 1.2 Ah (34-025) (Portalac model #
PE6V1.2)
Standard class 2, 9 VAC, 3.34 A power transformer (UTC Fire & Security Part
22-153). Alternate transformer for US installations: MG Electronics Model
MGT925, 9 VAC, 25 VA, (UTC Fire & Security Part 22-155).
Hardwired siren (13-374)
Household burglary alarm system unit (UL 1023), basic system plus the
following:
Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode
door/window sensor (60-670)
Panel piezo beeps set to on
Entry delay set to 45 seconds or less
Exit delay set to 60 seconds or less
RF time-out set to 24 hours
Control panel alarms turned on
Autoarm set to on
Siren timeout set to five minutes or more
Trouble beeps set to on
RF jam detect set to on
Hardwired siren supervision set to on
Exit extension set to off
Quick exit set to off
Household fire warning system (UL 985), basic system plus the following:
Wireless smoke sensor 60-848-95 learned into sensor group 26
Panel piezo beeps turned on
Control panel alarms set to on
Siren timeout set to four minutes or more
Trouble beeps set to on
RF jam detect set to on