Chapter 4: Testing and troubleshooting
100 Concord 4 Installation Manual
Table 16 below describes pager sensor/zone number and user number report
codes.
Table 16: Pager sensor/zone code and numbers
Sensor/zone or user number
System event not caused by a zone or user
Sensor/zone numbers 1 to 96
Regular user codes 0 to 229 used
Partition master code used
Partition duress code used
System armed Itself (during service or power-up)
Outputs and sirens
You should test all outputs (onboard and SnapCard) to verify configuration
programming.
Note: Be sure to contact the central monitoring station before activating outputs
that trigger from an alarm condition.
To test outputs:
1. Contact the central monitoring station to inform them you are testing the
system.
2. Verify that all wiring at the panel and output devices is correct.
3. Activate the appropriate device to trigger each output as programmed.