Use these settings to program the output points of any installed
SuperBus 2000 hardwire output module. The installer programs a HOM
output point into the Concord security panel by entering three kinds of
information.
• Partition: The system partition (1 to 6).
•Trigger: The event that activates the output point. Trigger events can
be partition alarms, trouble conditions, open sensors, etc.
• Response: How the output responds to a trigger event.
Only the onboard and SnapCard outputs can be configured for user
control.
To program each of the HOM output point configurations into the
security panel:
1. With the display showing the desired bus device, press #.
2. Press A or B until the display shows OUTPUTS.
3. Press #. The display shows OUTPUT 1.
4. Press A or B to select an output, then press #. The display shows
PARTITION ASSIGN 1.
5. Press 1 to 6 to select the desired partition assignment for this relay.
The display flashes the entered setting. Press # and the display shows
the new setting.
6. Press A or B. The display shows CONFIGURATION tttrr
(current setting). The point configuration number is tttrr, where ttt is the
trigger number and rr is the response number.
7. Enter the desired five-digit configuration number for this relay. The
display flashes the entered setting. Press # and the display shows the
new setting.
8. Press # and repeat the process until all outputs are programmed.
This setting determines whether the selected touchpad sounds status
beeps. Each touchpad can be set individually. This feature is usually
turned off for a touchpad that is located in or near bedrooms, to avoid
disturbing sleeping persons.
This setting determines whether or not selected touchpads beep when
their buttons are pressed. This feature is usually turned off for a
touchpad that is located in or near bedrooms, to avoid disturbing
sleeping persons.
Komentáře k této Příručce