8 Monitor ISM/xL™ Hardware Guide
22-0375 rev1.1
2 Zone Wiring cont.
ORANGE Protection Point Input # 1
PURPLE Protection Point Input # 2
BLACK Input point
common connection.
Output power source
negative.
RED
GREEN
YELLOW
BLACK
"
B
"
C
o
n
n
e
c
t
BLUE Switching to GND Output.
To output driven device.
E.g. electronic siren with
built in driver.
Input # 1 e.g. Main entrance door contact.
Programmed and wired as normally open
with 2.2K end of line resistor.
Input # 2 e.g. Motion detector alarm contact.
Programmed and wired as normally closed.
Protection Input points 1 & 2 and Output Wiring Example
(+)(-- )
2.2 K
NC NO
CM
NC NO
CM
Keypad
Base
(back view)
Power
Supply
(+)
(-- )
Siren
Separate Data
A,B Cable
Separate
Power Cable
M
O
D
U
L
E
B
U
S
Common
Negative
Reference